beautypg.com

Stuart Turner PH 35 ES B User Manual

Page 8

background image

- 8 -

Cont ...

SITING OF THE PUMP/PIPEWORK

WARNINGS:

Pump Location

If possible site the pump in a location where in the unlikely event of a

liquid leak, any spillage is contained or routed to avoid electrics or

areas sensitive to liquid damage.

Care should be taken to protect pump from frost and freezing.

Ensure pipework to and from pump is independently supported to

prevent forces being transferred to inlet and outlet branches of pump.

Do not introduce solder flux to pumps or pump parts manufactured

from plastics. All solder joints should be completed and flux residues

removed prior to pump connection.

Do not allow plastic pump parts to come into contact with oil or

cellulose based paints, paint thinners or strippers, acid based

descalents or aggressive cleaning agents.

The motor casing can become very hot under normal operating

conditions, care should be taken to ensure it cannot be touched

during

operation.

Do not allow scale or debris to enter pump. Fit inline strainers to

eliminate the problem in systems at risk.

Always install isolating valves to both suction and delivery pipework.

Do not install a non-return valve, or devices

which contain non-return valves, in the

suction (inlet) pipework to the pump. The

pump must be free to vent to the supply

tanks at all time.

Exceptions can be made in the case of

suction lift installations when a footvalve is required, although under

these conditions it is recommended a suitable pressure relief valve is

fitted in the discharge (outlet) pipework from the pump.

General

Locate the pump in a frost free horizontal position where it cannot be sprayed with water

and as close to the liquid source as possible.

The pump enclosure must be ventilated and there should be a minimum clearance of

80 mm between the pump and housing on all sides.

Care must be taken when mounting the pump that any noise is not amplified through

loose panels, pipework or other mounting medium. Noise transmission in pipework can
be reduced by fitting flexible hoses to pump inlet and outlet ports and by placing the pump
on anti-vibration mounting feet. Resilient mounting feet and flexible hoses are available
separately as optional extras, contact Stuart Turner for further details.

Ensure the liquid flow is in the direction of the arrows that are moulded onto the reed

switch assembly (vertically upwards) (Fig. 6).

The pump set must be mounted in the horizontal position on its feet, with the discharge

port in the vertical position and must not be mounted in any other way (on its side for
instance).

This manual is related to the following products: