TECHNICAL SPECIFICATION

Stuart Turner reserve the right to amend the specification in line with its policy of

continuous development of its products.

Note: For information on other voltages/frequencies which are not shown, consult any

supplementary instruction sheet supplied, or the rating label attached to the

pump.

SITING OF THE PUMP/PIPEWORK

WARNINGS:

Pump Location

If possible site the pump in a location where in the unlikely event of a

liquid leak, any spillage is contained or routed to avoid electrics or

areas sensitive to liquid damage.

Care should be taken to protect the pump from frost and freezing.

Ensure pipework to and from pump is independently supported to

prevent stress on the pump inlet and outlet branches.

Do not fit a non-return valve, or devices which contain non-return

valves, in the suction (inlet) pipework to the pump. Exceptions can be

made in the case of suction lift installations when a footvalve is

required.

When a footvalve is required on installations that incorporate

automatic pump control, it is recommended that a suitable pressure

relief valve be fitted in the discharge (outlet) pipework from the pump.

Do not run against a closed valve for periods longer than 5 minutes.

LIMITS OF APPLICATION

Part

No

Model

Supply

Max.

Liquid

Temp.

o

C

Min.

Liquid

Temp.

o

C

Max.

Ambient

Air Temp

o

C

Max.

Suction

Lift (m)

Max. Head

(Pump Closed

Valve) (m)

Max. Viscosity

**Max.

Working

Pressure

kPa (bar)

Max. Inlet Head

(m)

Max. No.

Starts/h

50 Hz

60 Hz

(Redwood

No. 1 Scale)

Centistokes

50 Hz

60 Hz

46628

PH 45 TS S

230/1/50

80

4

40

4.6*

40

50

9.5

600 (6)

21

60

46629

PH 45 TS S

230/1/50

80

4

40

4.6*

40

50

9.5

600 (6)

21

60

Part

No

Model

Supply

Nominal

Watts

Output

(Motor)

Max. Watts

consumed

Full Load

(AMPS)

Enc.

Rating

Duty Rating

Dims (mm)

Gross

Weight

(packed)

kg

Connections

50 Hz

60 Hz

50 Hz

60 Hz

L

W

H

Suction Delivery

46628

PH 45 TS S

230/1/50

370

518

2.4

IP44

Continuous

(S1) @ 2.5

l/min & above

249

130

166

6.5

G¾ M

G¾ M

46629

PH 45 TS S

230/1/50

370

518

2.4

IP44

Continuous

(S1) @ 2.5

l/min & above

249

130

166

6.5

G¾ M