4.14

Starting the pump:

a) Ensure all outlets are closed, turn power supply ‘on’ - pump will start,

pressurise the system then stop.

b) Open and close all outlets in turn associated with the pump, allowing water to

flow from each outlet until all air is purged. As each outlet is opened and

closed, the pump will start and stop respectively.

Note: After closing the outlet there will be a small time delay before the pump

stops, which is normal.

c) Any tap or control valve within the system when opened and closed will now

turn the pump on/off. Providing this is the case the system is now operating

correctly.

d) Carefully check pump and pipework for leaks whilst pump running and

stationary before leaving the installation unattended.

Do not run pump without guards and terminal box lid correctly

fitted.

The pump chamber must be full of water at all times. Seal

damage will result if the pump runs dry.

4.15

For Further Technical Support: Phone the Stuart Turner Pump Assist team

on 0844 98 000 97. Our staff are trained to help and advise you over the phone.

4 COMMISSIONING

4.11

System Flushing

The pipework system should be flushed out prior to the pump

being connected to ensure any contaminants/chemical residues

and foreign bodies are removed from elsewhere in the system.

4.12

Water Supply: Always ensure that water storage capacity is adequate to meet

the demand. Ensure the pump chamber is full of water before starting the pump.

Failure to do this could result in seal damage. To ensure dry running does not

occur the pump must be primed as described in priming section below.

Do not run pump dry.

4.13

Priming: Prior to switching the

pump on and connecting the

outlet hoses to the system

pipework the pump chamber

must be primed. The pump must

be primed (filled with water)

before starting. Turn on water

supply, prime and vent the pump

by unscrewing the priming plug

(Fig. 6) slowly until all air escapes

and water emerges. Re-tighten

the

plug.

Jet 55-45 PS, Jet 80-45 PS Fig. 6

Priming/
vent Plug

Drain
Plug