3 PUMP

CONNECTIONS

Do not use stainless steel, chrome or nickel plated pipe with the

flexible hose push-in plumbing connections.

Do not introduce solder flux into the joint or surrounding area as

connectors will be attacked and may fail.

All solder joints should be completed and flux residues removed

before final connection to push-in connections, on the flexible hose.

Do not allow contact with oil or cellulose based paints, paint

thinners or strippers, acid based descalents or aggressive cleaning

agents.

Never operate pump with inlet and/or outlet isolating valves in the

closed position. Damage will occur!

3.11

Hose to pump: The pump inlet and outlet ports have moulded fittings which

are specifically designed for connection to the G ¾ female running nuts on the

flexible hoses supplied. The hose end running nut is fitted with a rubber sealing

washer which is held captive within the nut assembly. Locate the hose into

position and screw the nut fully onto the fitting by hand. Finally nip tight with

pliers (4/5 Nm) for a water tight seal

(do not overtighten).

Fig. 8

Rubber sealing
washer (captive
in nut assembly)

Outlet

Inlet

Filter