5 COMMISSIONING
5.11
System Flushing: This pump incorporates push-in connectors
and plastic components that must not come into contact with
solder flux, acid-based descalents or aggressive cleaning agents.
The pipework system should be flushed out prior to the pump
being connected to ensure any contaminants/chemical residues
and foreign bodies are removed from elsewhere in the system.
5.12
Water Supply: Always ensure that water storage capacity is adequate to meet
the demand. Ensure the pump chamber is full of water before starting the pump.
Failure to do this could result in seal damage. To ensure dry running does not
occur the pump must be primed as described in priming section below.
Do not run pump dry.
5.13
Priming: The pump must be primed (filled with water) before starting. Turn on
water supply from the system service valves, prime and vent the pump by
opening the pump inlet and outlet isolating valves to allow pump to fill and vent.
In the case of twin pumps, both pump chambers must be independently primed.
5.14
Starting:
a) Ensure all outlets are closed, turn power supply ‘on’.
b) Open and close the pumped outlet allowing water to flow until all air is purged.
As the outlet is opened and closed, the pump will start and stop respectively.
c) When opened and closed the pumped outlet will now turn the pump on/off. If
this is confirmed to be the case, the system is now operating correctly.
d) Carefully check pump and pipework for leaks whilst pump running and
stationary before leaving the installation unattended.