MAHLE RTI BFX-2 User Manual
Page 6

Page 5
N E W
T A N K
= # #
O Z
S E L E C T
P R O C E S S
N E W
T A N K
= # #
O Z
E M P T Y I N G
M C
N E W
T A N K
= # #
O Z
S E L E C T
P R O C E S S
N E W
T A N K
E M P T Y
P R E S S
C O N T I N U E
S E L E C T
N E W
T A N K
3 2 O Z
4 8 O Z
6 4 O Z
I N S T A L L
B O T T L E
P R E S S
C O N T I N U E
R E M A I N I N G
= # #
O Z
F I L L I N G
M C
Amount
LF
RF
LR
RR
64 oz
6
6
7
7
48 oz
5
5
6
6
32 oz
4
4
5
5
³ This will display.
Press EMPTY MASTER CYLINDER.
³ This will display.
Use Vacuum Hose to remove all fluid from the
master cylinder.
Press EMPTY MASTER CYLINDER to end the
process.
IMPORTANT: Place end of Vacuum Hose on
Parking Stud before proceeding to next step.
³ This will display.
Connect Fill Gun to Fill Hose.
Press FILL MASTER CYLINDER.
Buzzer will beep three times.
³ This will display.
Press CONTINUE.
³ This will display.
Use right arrow key
| to select size of
new fluid container.
Fluid amount entered controls amount of fluid
dispensed through bleeders (see Chart
Below).
Press CONTINUE
³ This will display.
Install New Fluid Float Switch in bottle of brake
fluid.
Press CONTINUE.
³ This will display.
Place nozzle of Fill Gun into the Master
Cylinder and squeeze trigger. Remaining
ounces will be displayed.
Release trigger when master cylinder is filled
to proper level.
Press FILL MASTER CYLINDER to stop the
process.
Hold Fill Gun over Master Cylinder and
squeeze trigger to relieve pressure.
Replace Master Cylinder cap and disconnect
Fill Gun.