Empty New Tank
1.
Turn all panel valves to the Home position.
2.
Connect shop air to VCX Shop Air Coupler.
3.
Close Cone Adapter Valve.
4.
Turn the appropriate New Tank Valve to empty from the corresponding tank. Note that New Tank 1
is used in the illustration shown below.
5.
Turn all panel valves to the Empty New Tank position shown in the illustration below. This orientation
can also be obtained by positioning the panel valves toward the blue highlights closest to each valve.
6.
Place the end of the clear hose into a bulk storage container and open the Cone Adapter Valve.
7.
Coolant will begin leaving the VCX from the New Coolant Tank through the clear hose. Be cautious
not to spill coolant onto the floor as the hose may “jump” when the New Coolant Tank is nearing
emptiness. Clean up any spills that may occur immediately.
8.
Once the Waste Coolant Tank is empty, close the Cone Adapter Valve and turn all valves to the
Home position.
New
Waste
3
New
New
1
2
Clear Hose
Bulk Waste Container
Cone Adapter
Valve
AFTER EVERY PROCEDURE
TURN ALL VALVES TO HOME
HOME
FILL NEW TANK
EMPTY NEW TANK
EMPTY WASTE TANK
EMPTY WASTE TANK
(PRESSURE)
TOP OFF
EMPTY NEW TANK
EMPTY RADIATOR
(VACUUM)
EMPTY RADIATOR
FILL NEW TANK
TOP OFF
EMPTY NEW TANK
FILL RADIATOR
FILL NEW TANK
HOME
TOP OFF
VACUUM GAUGE
HOME
ON
HOME
HOME
ON
HOME
ON
NEW 2
NEW 1
NEW 3
SELECT NEW COOLANT SOURCE
TURN ONE VALVE ON TO
VCX- 4