Fill Radiator
Fill Radiator
1.
Turn all panel valves to the Home position.
2.
Connect shop air to VCX Shop Air Coupler.
3.
Turn all panel valves to the Fill Radiator position shown in the illustration below, this orientation can
also be obtained by positioning the panel valves toward the magenta highlights closest to each valve.
Verify that the Cone Adapter Valve is open.
4.
Turn the appropriate New Tank Valve to fill from the corresponding tank. Note that New Tank 1 is
used in the illustration shown below.
5.
New coolant is automatically pulled out of the VCX New Coolant Tank and into the vehicle radiator
through the clear hose.
NOTE: IF THE CONE ADAPTER BECOMES DISLODGED BEFORE YOU CAN BEGIN THIS
PROCESS YOU MUST RERUN THE EMPTY RADIATOR FUNCTION, WITHOUT STARTING
THE VEHICLE, TO REGAIN THE VACUUM NEEDED TO FILL THE VEHICLE COOLANT
SYSTEM.
6.
Once the coolant stops moving through the clear hose turn all of the panel valves back to the Home
position and remove the Cone Adapter from the radiator.
7.
Turn all valves to the Home position.
8.
Close the Cone Adapter Valve.
New
Waste
3
New
1
Engine
Block
PINCH
HOSE
Radiator
Clear Hose
Plug Adapter
Overflow
Cone
Hose
Pump
Water
2
New
AFTER EVERY PROCEDURE
TURN ALL VALVES TO HOME
HOME
FILL NEW TANK
EMPTY NEW TANK
EMPTY WASTE TANK
EMPTY WASTE TANK
(PRESSURE)
TOP OFF
EMPTY NEW TANK
EMPTY RADIATOR
(VACUUM)
EMPTY RADIATOR
FILL NEW TANK
TOP OFF
EMPTY NEW TANK
FILL RADIATOR
FILL NEW TANK
HOME
TOP OFF
VACUUM GAUGE
HOME
ON
HOME
HOME
ON
HOME
ON
NEW 2
NEW 1
NEW 3
SELECT NEW COOLANT SOURCE
TURN ONE VALVE ON TO
VCX- 4