beautypg.com

Coolant replacement – MAHLE RTI MCX-2 (Rev F) User Manual

Page 11

background image

Page 10

16

16

12

14

6

8

4
2

10

2

10

6
4

8

12

14

28

22

24

18

20

26

LITERS

30

24

20
18

22

26

28

QUARTS

8 Quarts

If the pump is running and the new coolant level does not go down:

Try reversing the connections of the green and black hoses.

COOLANT REPLACEMENT

4. Set one of the Level Magnets at the fluid level in the New Coolant Tank (24 in above

drawing). Determine the amount of coolant to be exchanged (8 Quarts for example)
and position the other Level Magnet that many quarts below the other magnet (16
in above drawing).

5. Turn control valve to EXCHANGE COOLANT.

6. Press the top of EXCHANGE COOLANT OR FILL RADIATOR & OVERFLOW

selector switch to turn on the pump.

7. Watch the level of coolant as it lowers in the New Coolant Tank. Press the bottom

of the EXCHANGE COOLANT OR FILL RADIATOR & OVERFLOW selector switch
when it reaches the lower Level Magnet. This will stop the transfer of coolant.