Connecting to the transmission system, Important – MAHLE RTI ATX-2PS User Manual
Page 7
Page 6
IMPORTANT
Check transmission fluid level according to manufacturer’s
instructions before connecting the ATX-2
Adjust fluid level if required
90° Adapter Hose
12 inch
Straight Adapter Hose
New Fluid Sight Indicator
Transmission
Fitting
Radiator
12 inch
Adapters
Cooler Lines
CONNECTING TO THE TRANSMISSION SYSTEM
1.
Add desired amount of transmission fluid to the new fluid tank through the ATX-2 fill port. Monitor
fluid level in the ATX-2 through the Level Indicator.
2.
Locate and disconnect the transmission cooler lines at the most convenient location:
A.
At cooler line connecting to radiator usually most accessible if vehicle is not on lift.
B.
At clamped rubber hose connection to transmission cooler usually most accessible if
vehicle is on a lift. Cooler is most often in front of the radiator.
C.
At cooler line connecting to the transmission usually requires vehicle to be on a lift.