TEST INSTALLED FAUCET

1. Setting the Detection Zone (Distance): Fig. 1.

Detection Zone: 2" - 10" (50mm - 250mm)

Default: Set at Factory 6" (150mm)

Remove cover from ENCLOSURE. Disconnect GRAY

SENSOR WIRE

(1) from circuit board, then reconnect.

Fig. 2.

2. While the SENSOR CONTROL LED (2) is blinking

slowly, place your hand 1 - 2 in. (30-50mm) in front of

the sensor.

Fig. 2a.

3. When the LED stops blinking and stays "ON", move

your hand to the desired position and hold in place until

the LED begins to blink again.

Fig. 2a.

4. Once the SENSOR CONTROL LED (2) begins to

blink again, remove your hand from the detection zone.

When the flashing stops, the detection distance is set.

Fig. 2a.

TO ENSURE A LAMINAR WATER FLOW the air must

be slowly purged from the spout. To do so, cover the

SENSOR

(1) while slowly opening the water supply

valves. When the water flows as a solid, smooth,

steady stream, uncover the SENSOR

(1) and fully

open the water supply valve.

Fig. 1.

HOW TO CHANGE SENSOR

RANGE; (Factory set at 6") Fig. 2

1

Fig 1

Fig. 2a

1" - 2" (30mm - 50mm

BLINKING LED

UP TO 10" (250mm)

BLINKING

LED

2

2

1. Remove ENCLOSURE COVER.

2. Close SUPPLY STOP (5) with 4mm Hex wrench.

Note: Keep water flowing out of faucet while shutting off.

3. Pull off Red (1) and Black (2) CONNECTORS from

SOLENOID VALVE

(3).

4. Unthread STRAINER (4) using a 7/16" socket.

5. Pull out the STRAINER (4) and clean with an old

toothbrush. Rinse thoroughly with water.

6. Install the STRAINER (4) back in its place and

tighten with a 7/16" socket.

Caution: do not over tighten strainer.

Note: It is recommended to clean strainer every 6

months.

7. Replace ENCLOSURE COVER. Tighten cover

screws firmly.

HOW TO CLEAN FILTER; Fig. 3

CAUTION

Before opening ENCLOSURE

disconnect AC power supply.

DETECTION

ZONE

MAINTENANCE

When the Sensor detects a user, the water

immediately starts to flow. Water flow will stop Two

seconds after user is out of sensor range. The off delay

allows the user to comfortably move his hands without

the flow cycling on to off. As a precaution, a safety

timer will turn off the water, after the sensor has been

blocked for 59 seconds. The water will stay off until the

blockage is removed from the detection zone.