PROCESS PARAMETERS
The nitrogen production depends on these parameters:
Flow rate
The lower the flow rate of compressed air through the hollow fiber membrane, the
more oxygen can permeate through the membrane wall. As a result, the nitrogen
produced at the outlet will have a higher purity. Nitrogen purity can be adjusted with
the flow control valve.
Temperature
The NTF-230 operates at a temperature between 40-110
0
F (70-80
0
F optimally). If
the temperature increases, the pressurized air consumption will also increase. Do
not place the system in a room where the temperature may rise unnecessarily high.
Membrane
pressure
Allow enough piping between the compressor exit and the NTF-230 inlet so that the
hot compressed gas has time to cool within the specifications listed in this manual.
A higher membrane pressure will increase the capacity (i.e. nitrogen output) of the
NTF-230.
External
pressure
There must be atmospheric pressure at the outlet. The capacity and the purity of
the nitrogen gas decreases strongly if the vent pressure exceeds the atmospheric
pressure.
CLEAN SHOP AIR – PROPER FLOW & PRESSURE
Many shop air supplies have an oiler installed to provide lubrication for air tools. The life of the filters in
the NTF-230 will be increased if the shop air supply is free from moisture and oil.
Recommendation - install a separate air line without an oiler to connect to the NTF-230. If this is not
practical, consider installing a separate pre-filter before connecting the NTF-230 to limit potential
contamination to the NTF-230 filters.
Also, ensure the shop air supply meets the pressure and flow ratings stated in the NTF-230 Operation
Manual for maximum nitrogen generation.
... IMPORTANT ...
The condition of the Filter Element (mounted on front of unit) can
only be checked when shop air is connected to the unit and the
valve is turned so the handle is HORIZONTAL so Nitrogen is being
generated and filling the tank. At all other times the Indicator will
not be visible.
The Filter Element must be changed when the indicator moves into
the CHANGE area and at least annually to protect the membrane
warranty.