RHS 900
Test - 1:
High pressure
8 - 9 bar
Low pressure
Approx.
0.8 bar
Fault/Problem Symptom
Possible
cause
Remedy
Unsatisfactory
refrigeration
Conditioned air not
cold
Air bubbles in sight
glass
Leakage in A/C unit
Insufficient refrigerant
in A/C unit
Locate leak and
repair
Replenish with
refrigerant
Test - 2:
High pressure
Approx.
20 bar
Low presure
Approx.
2.5 bar
Fault/Problem Symptom
Possible
cause
Remedy
Unsatisfactory
refrigeration
Insufficient
condenser
cooling
Fan does not run
Condenser performance
impaired by oil or dirt
deposits
Insufficient oil in A/C
unit (compressor fric-
tion)
Refrigerant overcharge
Clean condenser
Repair fan
Clean condenser
Replenish oil
check the refrigerant
quantity in the A/C unit -
empty the A/C unit,
evacuate and recharge thr
correct quantity
If none of these remedies
are successful, check the
refrigerant quantity in the
A/C unit - empty the A/C
unit, evacuate and
recharge