Trouble shooting, Evacuation process, Charging process – MAHLE RTI RHS900 User Manual
Page 41

- 11.2 -
Trouble shooting
C:\RHS Computer Files\Instructions\RHS\GB\642-40\0012B-01.doc 1997.09.11
RHS 900
Evacuation process:
Problem Fault
Remedy
Vacuum pump does not
run
1. RHS 900 not cut in
2. Overpressure in A/C unit
3. Internal component fault
1. Cut in RHS 900
2. Cut in recovery process
3. Contact RHS 900 supplier
Vacuum pump runs but
does not build up enough
vacuum
1. Service couplings not fitted correctly
2. A/C unit defective/leaking
3. Internal component fault
1. Fit service couplings correctly
2. Repair A/C unit
3. Contact RHS 900 supplier
Charging process:
Problem Fault
Remedy
No refrigerant flow
1. High-pressure valve on service coupling
not opened
2. Internal component fault
1. Open valve
2. Contact RHS 900 supplier!
Lamps "Vacuum OK"
and "Vacuum fault" light
up together
1. Solenoid valve Y14 in RHS 900 leaking
1. Replace valve or contact RHS 900 supplier