Before use – MAHLE RTI RHS700 User Manual
Page 8

- 4.1 -
Before use
C:\RHS Computer Files\Instructions\RHS\GB\645-40\0009A-01.doc 1997.03.26
RHS 700
Check the following:
-
whether the station has been damaged in transit - if so, contact supplier
immediately;
-
oil level in vacuum pump: it must not be below the centre of the sight glass.
If the level is too low, see section MAINTENANCE for vacuum oil
replenishment instructions;
-
whether the mains supply is as stated on the station nameplate;
-
whether the refrigerant in the A/C unit is as stated on the station nameplate.
Preparation:
-
Connect mains plug to mains supply.
-
Connect the red and blue hoses to their stubs on the rear of the station. Blue
hose to low-pressure side, red hose to high-pressure side. (See the next two
pages.)
-
Make sure that the shut-off valves on hoses and pos. 5 are closed.
-
Connect high and low-pressure hoses to their respective sides (using the
service couplings) on the A/C unit. (See the next two pages.)
-
RHS 700 is now ready for operation.