CAUTION: Maintenance

DISASSEMBLY

1. Replacement parts may be available at the store where

you purchased your faucet.

2. When replacement parts are not available, please write or

call Price Pfister Consumer Service.

3. Always turn off water and relieve pressure before

working on your faucet.

NOTE: Trim Care

Cleaning Instructions:

For all Handles and decorative finishes, use only a soft damp

cloth to clean and shine. Use of polish, detergents, abrasive

cleaners, organic solvents or acid may cause damage. Use

of other than a soft damp cloth will nullify our warranty!

Special Trim:

Trim products which contain Porcelain or other similar

substance are not acceptable for public areas or Commercial

use. Installation of Said Trim is at Users Risk!

6 HANDLE ATTACHMENT (Fig.C)

Place Handle Hub (1) on Valve Stem (3) and secure with

Set Screw (2) (do not over tighten).
7 SPOUT INSTALLATION (Fig.D)

Place Flange (1) into Spout Shank (2). Screw Spout Shank

(2) into Pipe Nipple and tighten until Spout (3) is properly

positioned to the finished wall. Secure using Set Screws

(4) as shown.
8 CLEANING THE AERATOR (Fig.E)

It is advisable to periodically clean the aerator, in order

to avoid build-up of dirt and limestone, which in time

could gradually limit the water flow. To clean the Aerator,

disassemble Aerator Housing by separating the Aerator

Head (5), Basket (6) and Washer (7). Once parts have been

cleaned, reassemble by reversing steps.
9 UNIT START UP

Turn on hot and cold water supplies, and check all connections

for leaks.
10 CARTRIDGE REMOVAL(Fig.F)

Turn off water supplies and relieve pressure before

working on your faucet! Loosen Set Screw (1) and

remove Handle (2). Remove the Dome Cap (3) by

unscrewing counterclockwise. Carefully remove the

Cartridge (4) by pulling it straight up and out. Reassemble

valve by reversing steps.