Appendix, Specifications, Controllers – Watlow Control Console User Manual
Page 8: Output power switching, Power requirements, Sensor input, Operating environment, Dimensions of enclosure
6
■
C o n t r o l C o n s o l e
Wa t l o w
Appendix
Specifications
Controllers
• Watlow Series 96 (Refer to Series 96 User's
Manual for controller specifications.)
• Watlow Series SD (1/16 or 1/32 DIN), (Refer to
Series SD User's Manual for controller/limit
specifications.)
• Watlow Series 97 (Refer to Series 97 User's
Manual for controller/limit specifications.)
Power Requirements and Output Power
Switching
• Utilizes solid-state relay.
• Output is powered through the line cord.
• MINI, SNGL, and Light Duty DUAL Control
Consoles are fused at 10 amps total, 8 amp max-
imum total load is recommended.
• 120V have NEMA 5-15 plug
• 208/240V have NEMA 6-15 plug
• Heavy Duty DUAL Control Consoles are fused at
20 amps total, 16 amp maximum total load is
recommended. Each zone is individually fused at
10 amps with 8 amps maximum load recom-
mended.
• NEMA 5-20 plug
• Heavy Duty Controller/Limit Consoles are fused
at 15 amps with 12 amps maximum load recom-
mended.
• Light Duty Controller/Limit Consoles are fused
at 10 amps with 8 amps maximum load recom-
mended.
• QUAD consoles are fused at 20 amps total with
16 amps maximum load recommended. Each
zone is individually fused at 5 amps with 4 amps
maximum load recommended.
• All models are available with 120V~ +10%/-15%.
• MINI, SNGL and Light Duty DUAL consoles are
available with 208/240V~ +10%.
• 208/240V fused for domestic use only (both lines
fused).
Sensor Input
• Factory selectable thermocouple (J, K or T) or 2-
wire RTD.
• RTD for Series SD series only available as 100-
ohm, platinum DIN curve.
• Series 96 has option of DIN or JIS curve, which
can be selected by user.
• Choice of AMP Mate-'n'-Lok® connector(s) or
twist-and-lock connector(s) for heater output(s).
• Mating connector(s) provided.
• EIA-232 communications available in SNGL con-
trol consoles with a Series 96 controller.
• EIA-485 communications are available in DUAL
and QUAD Control Consoles with a Series 96
controller.
• EIA-485 to EIA-232 communications converters
and power supplies are available from Watlow.
Operating Environment
• 0 to 45°C (32 to 113°F)
• 0 to 90% RH, noncondensing
Dimensions of Enclosure
Console
Height
Width
Depth
Mini
76 mm
90 mm
180 mm
3.0 in
3.5 in
7.1 in
Single 119 mm
76 mm
191 mm
4.7 in
3.0 in
7.5 in
Dual
121 mm
152 mm
187 mm
4.75 in
6.0 in
7.375 in (SD)
Quad
114 mm
305 mm
191 mm
4.5 in
12.0 in
7.5 in