Appendix, Specifications, Controllers – Watlow Control Console User Manual

Page 8: Output power switching, Power requirements, Sensor input, Operating environment, Dimensions of enclosure

background image

6

C o n t r o l C o n s o l e

Wa t l o w

Appendix

Specifications

Controllers

• Watlow Series 96 (Refer to Series 96 User's

Manual for controller specifications.)

• Watlow Series SD (1/16 or 1/32 DIN), (Refer to

Series SD User's Manual for controller/limit
specifications.)

• Watlow Series 97 (Refer to Series 97 User's

Manual for controller/limit specifications.)

Power Requirements and Output Power

Switching

• Utilizes solid-state relay.

• Output is powered through the line cord.

• MINI, SNGL, and Light Duty DUAL Control

Consoles are fused at 10 amps total, 8 amp max-
imum total load is recommended.

• 120V have NEMA 5-15 plug

• 208/240V have NEMA 6-15 plug

• Heavy Duty DUAL Control Consoles are fused at

20 amps total, 16 amp maximum total load is
recommended. Each zone is individually fused at
10 amps with 8 amps maximum load recom-
mended.

• NEMA 5-20 plug

• Heavy Duty Controller/Limit Consoles are fused

at 15 amps with 12 amps maximum load recom-
mended.

• Light Duty Controller/Limit Consoles are fused

at 10 amps with 8 amps maximum load recom-
mended.

• QUAD consoles are fused at 20 amps total with

16 amps maximum load recommended. Each
zone is individually fused at 5 amps with 4 amps
maximum load recommended.

• All models are available with 120V~ +10%/-15%.

• MINI, SNGL and Light Duty DUAL consoles are

available with 208/240V~ +10%.

• 208/240V fused for domestic use only (both lines

fused).

Sensor Input

• Factory selectable thermocouple (J, K or T) or 2-

wire RTD.

• RTD for Series SD series only available as 100-

ohm, platinum DIN curve.

• Series 96 has option of DIN or JIS curve, which

can be selected by user.

• Choice of AMP Mate-'n'-Lok® connector(s) or

twist-and-lock connector(s) for heater output(s).

• Mating connector(s) provided.

• EIA-232 communications available in SNGL con-

trol consoles with a Series 96 controller.

• EIA-485 communications are available in DUAL

and QUAD Control Consoles with a Series 96
controller.

• EIA-485 to EIA-232 communications converters

and power supplies are available from Watlow.

Operating Environment

• 0 to 45°C (32 to 113°F)

• 0 to 90% RH, noncondensing

Dimensions of Enclosure

Console

Height

Width

Depth

Mini

76 mm

90 mm

180 mm

3.0 in

3.5 in

7.1 in

Single 119 mm

76 mm

191 mm

4.7 in

3.0 in

7.5 in

Dual

121 mm

152 mm

187 mm

4.75 in

6.0 in

7.375 in (SD)

Quad

114 mm

305 mm

191 mm

4.5 in

12.0 in

7.5 in