PS-3710A / PS-3711A Reference Manual

3-6

Remote Reset Input

This is the reset signal sent from an external device to the PS-A. When this signal is enabled, a forced

reset of the PS-A is performed.

The System Monitor property of the control panel or the API-DLL can be used to enable or disable this

feature.

To enable Remote Reset Input, make sure to check the [Enable] in the [Remote reset] tab of

System Monitor Property. For Remote Reset of System Monitor Property, refer to the following.

Input Voltage

DC12V to DC24V

Input Method

Sink / Source Input

Input Current

10mA ( DC24V )

Input Resistance

3.6k

Input Points

5 points ( common with external reset input )

Operation Range

ON voltage

DC10V or more

OFF voltage

DC3V or less

Isolation Method

Photocoupler Isolation

Dielectric Strength Voltage

500V or more

• General-Purpose Input (DIN) level must be 1.5 seconds or longer to be detected. It

may not detect under 1.5 seconds.

• Be sure the voltage value between terminals is controlled via the input voltage, so

that the PS-A is operated within its recommended range. If the input voltage

exceeds this range, a malfunction or PS-A damage may occur.

• With Sink/Source input, even if the D(-), and RESET(-) are positive, and D(+),

RESET(+) are negative, no problems are created. Be sure to operate the unit within

the recommended voltage range.

For connection pin location details,

SEE

3.8.5 Remote Reset (page3-32)

(Interface Circuit)

+5V

1.8k

1/10W

1.8k

1/10W

R

R

PC357

No polarity - for Sink /
Source input

switch or other
switching device

Cable

DC12V
to 24V

RST(+) pin

#

5

DIN0(+) pin

#

6

DIN1(+) pin

#

13

DIN2(+) pin

#

16

DIN3(+) pin

#

18

RST(-) pin

#

11

DIN0(-) pin

#

12

DIN1(-) pin

#

17

DIN2(-) pin

#

23

DIN3(-) pin

#

24

SEE

PS-3710A/PS3711A Hardware Manual 2 Specifications