Pilot Solenoid Power Consumption (each solenoid): 6.0 watts on DC; 15.8 VA inrush and
10.4 VA holding on AC.
Solenoids: According to VDE 0580. Enclosure rating according to DIN 400 50 IP 65.
Connector socket according to DIN 43650 Form A. Three solenoids, rated for continuous duty.
Standard Voltages: 110 volts AC, 50/60 Hz; 24 volts DC.
Temperature Range:
Ambient: 15° to 122°F (4° to 50°C).
Media: 40° to 175°F (4° to 80°C).
Flow Media: Filtered (5 micron recommended), lubricated or unlubricated air (mineral oils
according to DIN 51519, viscosity classes 32-46).
Inlet Pressure: 30 to 116 psig (2 to 8 bar).
Pressure Switch (Status Indicator) Rating: Contacts - 5 amps at 250 volts AC, or 5 amps at
30 volts DC.
STANDARD SPECIFICATIONS
DIMENSIONS – inches (mm)
www.rosscontrols.com
1
2
4.87 (123.6)
2.66
(67.6)
.57
(14.5)
1.56
(40.0)
4.96 (126.1)
2.87 (72.6)
Valve Mounting Pattern
4.20
(106.6)
Valve
Mounting
Pattern
6.77
(172.0)
10.46
(265.7)
with
Status
Indicator