Pilot Solenoid Power Consumption (each solenoid): 6.0 watts on DC; 15.8 VA inrush and
10.4 VA holding on AC.
Solenoids: According to VDE 0580. Enclosure rating according to DIN 400 50 IP 65.
Connector socket according to DIN 43650 Form A. Three solenoids, rated for continuous duty.
Standard Voltages: 110 volts AC, 50/60 Hz; 24 volts DC.
Temperature Range:

Ambient: 15° to 122°F (4° to 50°C).

Media: 40° to 175°F (4° to 80°C).
Flow Media: Filtered (5 micron recommended), lubricated or unlubricated air (mineral oils
according to DIN 51519, viscosity classes 32-46).
Inlet Pressure: 30 to 116 psig (2 to 8 bar).
Pressure Switch (Status Indicator) Rating: Contacts - 5 amps at 250 volts AC, or 5 amps at
30 volts DC.

STANDARD SPECIFICATIONS

DIMENSIONS – inches (mm)

www.rosscontrols.com

1

2

4.87 (123.6)

2.66

(67.6)

.57

(14.5)

1.56

(40.0)

4.96 (126.1)

2.87 (72.6)

Valve Mounting Pattern

4.20

(106.6)

Valve

Mounting

Pattern

6.77

(172.0)

10.46

(265.7)

with

Status