Trouble Shooting Guide
Symptom
Cause and Solution
Difficult to wind or rewind
hose.
-
Hose was improperly wound back on reel, and the hose has over
lapped. Untangle the hose.
-
The hand crank tensioner is fully or partly engaged. Release hand
crank tensioner.
-
Insufficient grease in bearing. Add grease via grease fittings.
Leakage at inlet bearing.
-
O-ring has failed. Replace O-ring.
-
The spindle separated from the bearing. Replace O-ring and snap ring.
The drum wobbles.
-
The bearings are out of alignment. Loosen bearings, align the shaft,
and tighten the hardware.
-
The walls of the drum have been damaged. Straighten if minor, replace
drum if severe.
Guide rollers are binding.
-
The rollers have been bent or bowed. Replace damaged rollers.
-
Foreign material has become entangled in the ends of the rollers.
Remove rollers and clear debris.