Rapid-Air SERVO FEED GAG FEED: 950 SERIES User Manual
Page 24

23
Pressing the F4 key, stops the automatic cycle and the main menu screen appears. When 
the automatic screen is displayed, all keys except the F4 key are inactive. Every time the 
press cycles and trips the feed switch, the feed will cycle once per the parameters 
displayed on the screen. If the feed encounters excessive materail drag while feeding or 
the material being moved encounters a restriction taht stops the material forward 
movement then a servo fault can occur. If this happens then the following screen is 
displayed. 
 
 DRIVE FAULT OCCURED 
 NOTE TYPE OF FAULT—- 
 (xxx 
 *example of fault 
 2 - motor over temperature 
 
If this screen is displayed then the control cabinet has to be opened and the Pac-Sci drive 
has to be checked. To reset the fault, the master on-off switch has to be cycled which will 
reset the controller. The material path should be checked for obstruction and parrallelism 
to the die. If all this seems to be satisfactory and another fault occurs the factory should be 
consulted. 
 
 MAIN MENU 
 F1=JOB # F2=MANUAL 
 F3=AUTOMATIC CYCLE 
 F4=REVIEW JOB PROGRAM 
 F4=JOB REVIEW 
 
Pressing the F4 key will display the following screen. This screen asks for a sequence 
number to be reviewed or modified. The program only allows reviewing of a sequence in 
the job that is currently active. For an example, if job #1 had 4 sequences and sequnce 1 
was not functioning correctly then put ina 01 at this time. 
 
 REVIEW OR MODIFY SEQ 
 JOB NUMB=00 ENTER IN 
 THE SEQ=00 THEN 
 PRESS F4 TO CONTINUE 
 
Pressing the F4 key will display the following screen. 
 
 JOB#=00 SEQUENCE#=00 
 FL=000.000 REPEAT=00 
 OUT=00000000 PILOTS=0 
 SPEED=000 ACCEL=000 
 
The above screen displays the job number and the sequence that was selected. If all that 
was needed was to look at the sequence to verify that it was correct then pressing the F4 
key will return you to the main menu. If there was a problem with this particular 