18
OPERATOR INPUT TERMINAL - PROGRAMMING PROCEDURE-STANDARD
SOFTWARE
The intent of this section is to familiarize the operator with the program flow and what 
to expect with every keypress. Each screen on the display will be reviewed with 
special comments to help clarify what is being asked on the screen. The program flow 
is broken down into 5 sections with the main menu being the home postion. Reviewing 
the flow chart in the back of this manual will help in understanding the sections. 
SECTION1 —- F1=JOB ENTRY 
SECTION2 —- F2=MANUAL MODE 
SECTION3 —- F3=AUTOMATIC 
SECTION4 —-F4=REVIEW JOB PARAMETERS 
SECTION 5 —-RAMP=ADJUST ACCELLERATION AND DECELLERATION 
 
The first screen to be displayed on the operator terminal will look like this 
 RAPID-AIR CORPORATION 
 4601 KISHWAUKEE STREET 
 ROCKFORD, IL 61109 
 815-397-2578 
 
After a few seconds, the display will clear and the following display will appear: 
 MAIN MENU 
 F1=JOB F2=MANUAL 
 F3=AUTOMATIC CYCLE 
 F4=REVIEW JOB PROGRAM 
SELECT F1=JOB #
The first step in programming the servo feed is to select a job number which will be 
used to store the parameters the operator inputs or recall the parameters which have 
been previously loaded into the servo controller program. When the operator selects 
F1 on the keypad, the screen will change to: 
 JOB SELECTION MENU 
 ENTER JOB NUMBER=XX 
 PRESS F4 KEY ONCE 
 CORRECT # IS ENTERED 
 
The operator must enter a 2 digit number before proceeding to any other function. If 
the job number the operator has entered has been previously stored in memory, or 
entering a new job, the following display will appear: 
 JOB NUMBER-01 LOADED 
 F1=PROGRAM NEW VALUES 
 F4= DON’T ALTER VALUES 
 THAT ARE PREPROGRAMMED 