Rapid-Air SERVO FEED GAG FEED: 950 SERIES User Manual
Page 13

12
LOADING MATERIAL INTO THE SERVO FEED
Upon the satisfactory completion of all the tests, you should be ready to load a strip of 
material into the servo feed. 
 
Step number one is to select the manual mode of operation on the operators console. 
Then choose “Operate Rolls”. This will allow you to open the feed rolls and antibackup 
rolls to accept the material. You could also open the rolls manually by lifting the lever 
mounted on the side of the servo feed. Position the leading edge of the material with 
the center of the material near the center of the entry rolls. Adjust the edge guides on 
the cascade rolls to the proper width setting. Open the feed rolls and or anti-backup 
rolls. Hand feed the material into the servo unit until it protrudes out of the feed rolls 
and starts into the guide on the press. Close the anti-backup rolls (if purchased) to 
capture the material, then close the feed rolls. 
 
Check the roller force pressure to be sure that there is enough pressure to prevent 
slippage but not too much to induce camber into the material. The pressure setting is 
the amount of force necessary to move the material into the press at the speed and 
feed programmed. You may find it necessary to readjust the force as you finalize the 
setup procedure. The amount of force needed will vary depending on the width and 
type of material being fed. Make a note of the final setting to aid in the setup of the 
servo feed the next time the same material is run. 
 
You are now ready to begin testing the complete system under power. To check the 
progression, cycle the press in the single cycle mode with the servo feed in the 
automatic mode. If the progression is correct, no further adjustments are necessary. If 
the progression is either short or long, go to the troubleshooting chart and perform the 
sequences described there for inaccurate feeding, once the feed progression has been 
accuratelly set and the repeatability is satisfactory, you are ready for full automatic 
mode. 
 