beautypg.com

Typical layout – Ramsey Winch RPH-50000 LARGE FLANGE W/AIR TENSIONER (OBSOLETE) User Manual

Page 6

background image

3

HYDRAULIC SCHEMATIC


AIR SYSTEM REQUIREMENTS

The cable tensioner requires an independent, adjustable regulated air supply of between 50 and 90 PSI.

CAUTION: DO NOT EXCEED 100 PSI AIR PRESSURE TO THE ACTUATORS. THIS COULD CAUSE DAMAGE TO THE
ACTUATORS.

The clutch release cylinder requires an air supply of between 100 and 120 PSI.


CLUTCH OPERATION

To engage clutch:

1. Move the clutch control valve to the “clutch engaged” position.

2. Anytime the temperature is below freezing, run the motor in the “cable out” direction only until the drum

starts to turn. In extreme cold temperatures (below 0o F/-18o C), pull out on the cable by hand only until
the drum starts to turn.

3. Wait at least 3 seconds for the clutch to fully engage, after which the winch is ready to winch in the cable.

WARNING: Do not attempt to engage the clutch by first running the winch motor and then moving the clutch

control valve to the "clutch-engaged" position while the motor is running. Do not start picking up the load at the
same time the clutch is being engaged.

To disengage clutch:

1. Run the winch in the "cable out" direction until the load is off the cable.

2. Move the clutch control valve to the "clutch-disengaged" position.

3. The cable may now be pulled off by hand.

4 WAY VALVE

(MOTOR SPOOL)

DUAL-A & B PORT CONTROL

WITH BRAKE RELEASE SHUTTLE

ALTERNATE

CARTRIDGE

LOCATION

(AS DESCRIBED

IN VIEW A-A

ON PAGE 16)

MOTOR

BRAKE

PORT

3 POSITION

TYPICAL LAYOUT

SYSTEM

RELIEF

PUMP