3
HYDRAULIC SCHEMATIC
AIR SYSTEM REQUIREMENTS
The cable tensioner requires an independent, adjustable regulated air supply of between 50 and 90 PSI.
CAUTION: DO NOT EXCEED 100 PSI AIR PRESSURE TO THE ACTUATORS. THIS COULD CAUSE DAMAGE TO THE
ACTUATORS.
The clutch release cylinder requires an air supply of between 100 and 120 PSI.
CLUTCH OPERATION
To engage clutch:
1. Move the clutch control valve to the “clutch engaged” position.
2. Anytime the temperature is below freezing, run the motor in the “cable out” direction only until the drum
starts to turn. In extreme cold temperatures (below 0o F/-18o C), pull out on the cable by hand only until
the drum starts to turn.
3. Wait at least 3 seconds for the clutch to fully engage, after which the winch is ready to winch in the cable.
WARNING: Do not attempt to engage the clutch by first running the winch motor and then moving the clutch
control valve to the "clutch-engaged" position while the motor is running. Do not start picking up the load at the
same time the clutch is being engaged.
To disengage clutch:
1. Run the winch in the "cable out" direction until the load is off the cable.
2. Move the clutch control valve to the "clutch-disengaged" position.
3. The cable may now be pulled off by hand.
4 WAY VALVE
(MOTOR SPOOL)
DUAL-A & B PORT CONTROL
WITH BRAKE RELEASE SHUTTLE
ALTERNATE
CARTRIDGE
LOCATION
(AS DESCRIBED
IN VIEW A-A
ON PAGE 16)
MOTOR
BRAKE
PORT
3 POSITION
TYPICAL LAYOUT
SYSTEM
RELIEF
PUMP