Typical layout – Ramsey Winch RPH-30000 User Manual
Page 4
WINCH FRAME MOUNTING
Use (8) 5/8 inch diameter grade 5 or better bolts to attach mounting frame to wrecker.
CABLE INSTALLATION
1. Unwind cable by rolling it out along the ground to prevent kinking. Securely wrap end of
wire rope, opposite hook, with plastic or similar tape to prevent fraying.
2. Insert the end of cable, opposite hook end, into the hole in drum barrel. Secure cable to
drum barrel using setscrew furnished with winch. TIGHTEN SCREW SECURELY.
3. Carefully run the winch in the “reel-in” direction. Keeping the tension on the end of cable,
spool all the cable onto the cable drum, taking care to form neatly wrapped layers.
HYDRAULIC SYSTEM REQUIREMENTS
Refer to the performance charts below to properly match your hydraulic system to RPH 30000
winch performance. The charts consist of:
(1) Line pull (lbs.) first layer, vs. working pressure (PSI) and (2) Line speed, first layer (FPM)
vs. gallons per minute (GPM). Performance based on a motor displacement of 9.6 cubic
inches with 15 GPM maximum flow rate. See page 13 for motor port size.
2
CONTROL VALVE
3 POSITION
4 WAY VALVE
(MOTOR SPOOL)
HIGH PRESSURE LINE
DUAL-A & B PORT CONTROL
WITH BRAKE RELEASE SHUTTLE
BRAKE
PORT
B
MOTOR
A
TYPICAL LAYOUT
LOW PRESSURE LINE
PUMP