beautypg.com

Typical layout performance charts – Ramsey Winch RPH-12000 User Manual

Page 6

background image

HYDRAULIC SYSTEM REQUIREMENTS

Refer to the performance charts below to properly match your hydraulic system to the winch performance. The
charts consist of:

(1) Line Pull first layer (lb.) vs. Working Pressure (PSI)

(2) Line Speed, first layer (FPM) vs. flow (GPM)

SYSTEM REQUIREMENTS

2500 PSI RELIEF VALVE SETTING

15 GPM FLOW RATE

DO NOT EXCEED 20 GPM--MOTOR AND WINCH MAY BE DAMAGED

10 MICRON NOMINAL FILTRATION

SYSTEM

RELIEF

3 POSITION

4 WAY VALVE

(MOTOR SPOOL)

MAX. FLOW &
PRESSURE AT
RATED LOAD:
15 GPM
2500 PSI

HIGH PRESSURE LINE
(.50 I.D. MINIMUM)

LOW PRESSURE LINE
(.75 I.D. MINIMUM)

PUMP

PORT CONTROL

B

WITH BRAKE RELEASE SHUTTLE

MOTOR

BRAKE

PORT

A

FLOW (GPM)

2500

2000

2250

10

5

15

LINE PULL, FIRS

T LA

YE

R (LB.)

WORKING PRESSURE, PSI

AT 15 GPM

0

4000

2000

0

500

1000

1500

2000

2500

10000

6000

8000

12000

RELI

E

F

VA

LV

E SE

T

T

ING

LINE

S

P

E

E

D, FIRS

T LA

YE

R (ft/m

in)

FLOW (GPM)

5

0

0

10

5

10

15

30

15

20

25

35

6

TYPICAL LAYOUT

PERFORMANCE CHARTS