beautypg.com

Performance charts, Typical layout – Ramsey Winch HD-P8000 914178-0209 User Manual

Page 6

background image

HYDRAULIC SYSTEM REQUIREMENTS

Refer to the performance charts below to properly match your hydraulic system to the winch performance. The
charts consist of:

(1) Line Pull first layer (lb.) vs. Working Pressure (PSI)

(2) Line Speed, first layer (FPM) vs. flow (GPM)

SYSTEM REQUIREMENTS

MOTOR SPOOL (OPEN CENTER) CONTROL VALVE REQUIRED

2500 PSI RELIEF VALVE SETTING

15 GPM FLOW RATE

DO NOT EXCEED 20 GPM--MOTOR AND WINCH MAY BE DAMAGED

10 MICRON NOMINAL FILTRATION

PORT CONTROL

PUMP

(.75 I.D. MINIMUM)

LOW PRESSURE LINE

(.50 I.D. MINIMUM)

HIGH PRESSURE LINE

2500 PSI

15 GPM

RATED LOAD:

PRESSURE AT

MAX. FLOW &

(MOTOR SPOOL)

4 WAY VALVE

3 POSITION

RELIEF

SYSTEM

A

PORT

BRAKE

MOTOR

WITH BRAKE RELEASE SHUTTLE

TYPICAL LAYOUT

B

4

LIN

E

PU

L

L

-FIR

ST LAYER

(L

B)

LIN

E

SPEED

-FIR

S

T L

AYER

(FPM)

0

5

10

15

10

20

30

40

0

0

1000

2000

3000

4000

5000

6000

7000

8000

1000

2000

2500

50

1500

500