beautypg.com

Typical layout, Performance charts, Based on 24.9 cu. in. motor – Ramsey Winch HD-P10000 User Manual

Page 6

background image

HYDRAULIC SYSTEM REQUIREMENTS

Refer to the performance charts below to properly match your hydraulic system to the winch performance. The
charts consist of:

(1) Line Pull first layer (lb.) vs. Working Pressure (PSI)
(2) Line Speed, first layer (FPM) vs. flow (GPM)

SYSTEM REQUIREMENTS

MOTOR SPOOL (OPEN CENTER) CONTROL VALVE REQUIRED

2100 PSI RELIEF VALVE SETTING

15 GPM FLOW RATE

DO NOT EXCEED 20 GPM--MOTOR AND WINCH MAY BE DAMAGED

10 MICRON NOMINAL FILTRATION

B

TYPICAL LAYOUT

WITH BRAKE RELEASE SHUTTLE

MOTOR

BRAKE

PORT

A

SYSTEM

RELIEF

3 POSITION

4 WAY VALVE

(MOTOR SPOOL)

MAX. FLOW &
PRESSURE AT
RATED LOAD:
15 GPM
2500 PSI

HIGH PRESSURE LINE
(.50 I.D. MINIMUM)

LOW PRESSURE LINE
(.75 I.D. MINIMUM)

PUMP

PORT CONTROL

(DUAL CART.

VALVE OPTION)

4

WORKING PRESSURE (PSI) AT 15 GPM

FLOW (GPM)

LINE PULL-F

IRST

LAYER (LB)

LINE SPEED-F

IRST

LAYER (F

PM)

0

5

10

15

0

5

10

15

0

0

1000

2000

3000

4000

5000

6000

7000

8000

1000

2000

2500

BASED ON 24.9 CU. IN. MOTOR

1500

500

PERFORMANCE CHARTS

9000

10000