Installation – Lincoln Electric IMt10100 WIRE FEEDER WELDER 140_180 User Manual
Page 7
![background image](/manuals/357024/7/background.png)
A-1
A-1
INSTALLATION
WIRE FEEDER WELDERS (140, 180 MODELS)
TECHNICAL SPECIFICATIONS 180 Amp units (K2689-2)
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency
Input Current
230 V 60 Hz
20 Amps @ rated output
208 V 60 Hz
20 Amps @ rated output
Voltage/Duty Cycle
Current
Voltage at Rated Amperes
230 V 30%
130 Amps
20
208 V 30%
130 Amps
17
Welding Current Range
Open Circuit Voltage
Wire Speed Range
30-180 Amps
34 V
50 - 500 in/min.
(1.3 - 12.7 m/min.)
Input Voltage/Frequency Fuse or Breaker Size
1
Input Amps Power Cord
230 V 60 Hz
40 Amp Super Lag
20 50 Amp, 250 V,
Three Prong Plug
(NEMA Type 6-50P)
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
13.7 in
10.15 in
17.9 in
64 Ibs
347 mm
258 mm
454 mm
29 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.
OPERA
T
ORʼS MANUAL
140 Amp units (K2688-2)
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency
Input Current
120 V / 60 Hz
20 Amps @ rated output
Duty Cycle
Current
Voltage at Rated Amperes
20% Duty Cycle
90 Amps
19.5
Welding Current Range
Open Circuit Voltage
Wire Speed Range
30-140 Amps
33 V
50 - 500 in/min.
(1.3 - 12.7 m/min.)
Input Voltage/Frequency Fuse or Breaker Size
1,2
Input Amps
Power Cord Extension Cord
120 V 60 Hz 20 Amp
20
15 Amp, 125 V, 3 Conductor # 12 AWG
Three Prong Plug (4mm
2
) or Larger
(NEMA Type 5-15P) up to 50 ft.(15.2m)
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
13.7 in
10.15 in
17.9 in
54 Ibs
347 mm
258 mm
454 mm
24.5 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.