INSTALLATION

AC-225-S & AC/DC 225/125

6. Slide handle into position and secure by turning the locking

screw in until it is tight. The threaded end of the screw will
then pass against the inside of the handle and the head of the
screw will be completely inside the handle.

Type B - Holder with Round, Ribbed Handle

1.

Remove handle mounting screw and slide handle off
holder. Place handle over electrode cable.The longer cable
is used for the Electrode Cable and is located in the front of
machine upper hole as shown in Figure 1A.

2.

If electrode cable does not have a terminal on it, remove
insulation from electrode cable 1” ± 1/16” (25.4mm ±

1.6mm) from end.

3.

Back out clamp connecting screw and remove cable
connecting clamp.

4.

If electrode cable has a terminal attached (#10 clearance
hole), place terminal over cable connecting screw.
Otherwise, place bare end of electrode cable into holder
with cable strands divided equally on both sides of clamp
connecting screw.

5. Tighten cable connecting screw securely into clamp so clamp holds

cable in place.

6. Slide handle into position and secure with handle mounting screw.

Attaching Work Cable to Clamp

Insert work cable (with 5/16” clearance hole terminal) through strain
relief hole in work clamp and fasten securely with bolt and nut
provided. The shorter cable is used for the Work Cable and is located

in the front of the machine lower hole as shown below.

Electrode and Work Cable Replacement

Substitution of cables with larger sizes requiring connections to be
made internally is not recommended. Connections for additional
lengths or larger sizes should be properly made externally. Lincoln
Electric QD (Quick Disconnect) connectors are available for this
purpose.

If either cable requires replacement for other reasons, they should be
replaced with the appropriate Lincoln parts— and only by qualified
personnel.

Important Safety Note: Make sure insulation is secure and that
screws are tight and cannot be touched. If screw can be touched,
DO NOT USE HOLDER, contact your distributor.

Work
Cable

Lower Hole
with Shorter
Cable

Electrode
cable

Terminal or
bare strands

Handle mounting screw

Clamp connecting screw

Cable

Cable
connecting
clamp

Handle

1"

±

1/16"

This manual is related to the following products: