beautypg.com

Installation, Electrical output connections, Outback™ 145 output connections – Lincoln Electric IM10073 OUTBACK 145 User Manual

Page 11

background image

A-4

INSTALLATION

OUTBACK™ 145

A-4

®]

ELECTRICAL OUTPUT CONNECTIONS

See Figure A.1 for the location of the current control
dial, weld output terminals, ground stud, circuit break-
ers, 240 and 120 volt receptacles.

WELDING CABLE CONNECTIONS

Cable Size and Length

Be sure to use welding cables that are large enough.
The correct size and length becomes especially impor-
tant when you are welding at a distance from the
welder.

Table A.1 lists recommended cable sizes and lengths
for rated current and duty cycle. Length refers to the
distance from the welder to the work and back to the
welder. Cable diameters are increased for long cable
lengths to reduce voltage drops.

TOTAL COMBINED LENGTH OF

ELECTRODE AND WORK CABLES

Cable

Length

0-50 ft (0-15m)

50-100 ft (15-30 m)

100-150 ft (30-46 m)

150-200 ft (46-61 m)

200-250 ft (61-76m)

125 Amps

30% Duty Cycle

6 AWG

5 AWG

3 AWG

2 AWG

1 AWG

TABLE A.1

RECOMMENDED WELDING CABLE

SIZE AND LENGTH

1. CURRENT CONTROL DIAL
2. WELD OUTPUT TERMINALS (2)
3. GROUND STUD
4. CIRCUIT BREAKER 20 Amp

5. RECEPTACLE - 240 VOLT, 50 AMP
6. DUPLEX RECEPTACLE (2)- 120 VOLT, 20 AMP
7. HOURMETER
8. CHOKE LEVER

FIGURE A.1

OUTBACK™ 145 OUTPUT CONNECTIONS

1

2

7

4

6

5

3

8