background image

A-6

INSTALLATION

CLASSIC

®

300HE

A-6

BATTERY CHARGING

The Classic

®

300HE is equipped with a wet charged

battery. The charging current is automatically regulat-
ed when the battery is low (after starting the engine)
to a trickle current when the battery is fully charged.

When replacing, jumping or otherwise connecting the
battery to the battery cables, the proper polarity must
be observed. This system is NEGATIVE GROUND.

GASES FROM BATTERY can explode.
• Keep sparks, flame and cigarettes

away.

BATTERY ACID can burn eyes and
skin.
Wear gloves and eye protection and

be careful when boosting, charging or
working near battery.

To prevent EXPLOSION when:

a) Installing a new battery - disconnect the

negative cable from the old battery first and
connect the negative cable to the new battery
last.

b) Connecting a battery charger - remove the

battery from the welder by disconnecting the
negative cable first, then the positive cable and
battery clamp. When reinstalling, connect the
negative cable last.

c) Using a booster - connect the positive lead to

the battery first, then connect the negative lead to
the ground lead on the base.

To prevent ELECTRICAL DAMAGE when:

a) Installing a new battery.
b) Using a booster.

Use correct polarity - Negative Ground.

• To prevent BATTERY DISCHARGE, if you have an

ignition switch, turn it off when engine is not run-
ning.

• To prevent BATTERY BUCKLING, tighten nuts on

battery clamp until snug.

------------------------------------------------------------------------

WARNING