CONTROL BOX CB-WCS

3

2.1 Components

The CB-WCS consists of the following components (Fig.
2.1)
:
A Cover

B Housing

C Timer PC board

D Fuse 2A

E Connecting block

F Transformer

G Thermal relay

H Relay

I Fuse holder

J Main fuse

K Cap nut

L Cable gland

Fig. 2.1: Main components

2.2 Operation

The CB-WCS is a control box which supplies power to the
connected welding cable sensor WCS and extraction fan SF
2400. The CB-WCS arranges the extraction fan to switch on
and off automatically. To realise this, the WCS is to be
connected to the ground cable of a welding machine. When
the welding starts, the WCS sends a signal to the CB-WCS.
Subsequently, the extraction fan SF 2400 automatically
switches on. When the welding stops, the fan automatically
switches off. Depending on the specific circumstances and/
or the user’s wish, the start delay and the stop delay of the
fan can be adjusted.

General

The manufacturer does not accept any liability for damage
to the product or personal injury caused by non-observance
of the safety instructions in this manual, modifications made
to equipment or by negligence during installation, use,

maintenance and repair of the product mentioned on the
cover of this document and any corresponding accessories.
Specific working conditions or used accessories may
require additional safety instructions. Immediately contact
your supplier if you detect a potential hazard when using the
product.

User Manual

• Everyone working on or with the product must be familiar

with the contents of this manual and must strictly observe
the instructions herein. Management should instruct and
train the operators in accordance with the manual and
observe all instructions and directions given.

• Never change the order of steps-to-be-performed.
• Always keep the manual with the product.

Users

The use of this product is exclusively reserved to authorized,
trained and qualified users. Temporary personnel and
personnel in training can only use the product under
supervision and responsibility of management and trained
personnel such as skilled engineers.

Intended Use

1

The product has been designed exclusively to switch the
connected extraction fan on and off by the automatic start/
stop device WCS and to connect the WCS to the mains.
Using the product for other purposes is considered contrary
to its intended use. The manufacturer accepts no liability for
any damage or injury resulting from such use. The product
has been built in accordance with state-of-the-art standards
and recognized safety regulations. Only use the product in
mechanically sound condition in accordance with its
intended use and the instructions set forth in the user
manual.

Modifications

Modifications of this product, other than those specified in
this manual, are not allowed. Any unauthorized modification
will void the product warranty.

Use

If the product is used in combination with the in the
introduction of this manual mentioned products or machines
(see 1.3), the safety instruction in the documentation of
these products also apply.

2

PRODUCT DESCRIPTION

3

SAFETY

CAUTION!

The user of the product is always fully responsible
for observing the local safety instructions and
regulations.

1.

"Intended use" as laid down in EN-292-1 is the use for which the technical product
is suited as specified by the manufacturer, inclusive of his directions in the sales
brochure. In case of doubt it is the use which can be deducted from the
construction, the model and the function of the technical product which is
considered normal use. Operating the machine within the limits of its intended use
also involves observing the instructions in the user manual.