Operation – Lincoln Electric IM10132 FLEXTEC 650 User Manual

Page 28

background image

B-10

OPERATION

B-10

Voltage Display Meter – This display will display the pre-set
welding voltage when the machine is in the idle state. After
welding, the meter holds the actual voltage value for 5 sec-
onds. Output adjustment while in the "hold" period results in the
"prior to operation" characteristics stated above. The displays
blink indicating that the machine is in the "hold" period.

Output Control Local/Remote – When the control is set to
“LOCAL” (no remote potentiometer/control plugged into the 6
pin or 14 pin connectors), the output is controlled through the
Output Control Dial on the front of the FLEXTEC™ 650. Set
this switch to “REMOTE” when an external potentiometer/con-
trol is connected.

Output Control Dial

• When the Local/Remote is set to “LOCAL”, this dial sets the

welding voltage.

• When the Local/Remote is set to “REMOTE”, this dial is dis-

abled.

CV-Innershield

This weld mode is a constant voltage (CV) mode featuring con-
tinuous control from 10 to 45 volts. It is intended for the FCAW-
SS welding process and arc gouging.

Hot Start – Toggle from the “0” position to the “10” position to
provide more energy during the start of a weld.

Arc Control – The Arc Control regulates pinch effect. At the
minimum setting (-10), minimizes pinch and results in a soft
arc. At the maximum setting (+10), maximizes pinch effect and
results in a crisp arc.

Weld Terminals On/Remote

• When set to the “ON” position, the weld terminals are at

OCV (open circuit voltage) and ready to weld. This selection
is used for across the arc wire feeders.

• When set to the “REMOTE” position, output is enabled

through a remote trigger.

Amperage Display Meter – This display will display three
dashed lines when the machine is in the idle state. This indi-
cates that amperage is not settable in this weld mode. While
output is enabled, the actual welding amperage will be dis-
played. After welding, the meter holds the actual amperage
value for 5 seconds. Output adjustment while in the "hold" peri-
od results in the "prior to operation" characteristics stated
above. The displays blink indicating that the machine is in the
"hold" period.

Voltage Display Meter – This display will display the pre-set
welding voltage when the machine is in the idle state. After
welding, the meter holds the actual voltage value for 5 sec-
onds. Output adjustment while in the "hold" period results in the
"prior to operation" characteristics stated above. The displays
blink indicating that the machine is in the "hold" period.

Output Control Local/Remote – When the control is set to
“LOCAL” (no remote potentiometer/control plugged into the 6
pin or 14 pin connectors), the output is controlled through the
Output Control Dial on the front of the FLEXTEC™ 650. Set
this switch to “REMOTE” when an external potentiometer/con-
trol is connected.

Output Control Dial

• When the Local/Remote is set to “LOCAL”, this dial sets the

welding voltage.

• When the Local/Remote is set to “REMOTE”, this dial is dis-

abled.

CV-SAW

This weld mode is a constant voltage (CV) mode featuring con-
tinuous control from 10 to 45 volts. It is intended for the CV-
SAW submerged arc welding process.

Hot Start – Not used for this welding process.

Arc Control – Not used for this welding process .

Weld Terminals On/Remote

• When set to the “ON” position, the weld terminals are at

OCV (open circuit voltage) and ready to weld. This selection
is used for across the arc wire feeders.

• When set to the “REMOTE” position, output is enabled

through a remote trigger.

Amperage Display Meter – This display will display three
dashed lines when the machine is in the idle state. This indi-
cates that amperage is not settable in this weld mode. While
output is enabled, the actual welding amperage will be dis-
played. After welding, the meter holds the actual amperage
value for 5 seconds. Output adjustment while in the "hold" peri-
od results in the "prior to operation" characteristics stated
above. The displays blink indicating that the machine is in the
"hold" period.

Voltage Display Meter – This display will display the pre-set
welding voltage when the machine is in the idle state. After
welding, the meter holds the actual voltage value for 5 sec-
onds. Output adjustment while in the "hold" period results in the
"prior to operation" characteristics stated above. The displays
blink indicating that the machine is in the "hold" period.

Output Control Local/Remote – When the control is set to
“LOCAL” (no remote potentiometer/control plugged into the 6
pin or 14 pin connectors), the output is controlled through the
Output Control Dial on the front of the FLEXTEC™ 650. Set
this switch to “REMOTE” when an external potentiometer/con-
trol is connected.

Output Control Dial

• When the Local/Remote is set to “LOCAL”, this dial

sets the welding voltage.

• When the Local/Remote is set to “REMOTE”, this dial

is disabled.

FLEXTEC™ 650