A-5

INSTALLATION

A-5

FLEXTEC™ 650

Pin

A
B

C
D

E

F

Wiring

77 Remote potentiometer, 5K
76 Remote potentiometer, wiper
75 Remote potentiometer, common
Trigger, common
Trigger, input
Ground

CABLE CONNECTIONS

See FIGURE A.2 for locating 6-pin and 14-pin con-
nectors on the front of the FLEXTEC™ 650.

FIGURE A.2

Function

6-pin remote
control con-
nector for
remote or
hand/foot
amptrol.

A

E

C

F

B

D

6-PIN REMOTE CONTROL CONNECTOR

Pin

A
B

C
D

E

F

G

H

I

J

K

L

M

N

Wiring

115 VAC
Ground
Trigger, Common
Trigger input
77 Remote potentiometer, 5K
76 Remote potentiometer, wiper
75 Remote potentiometer, common
Voltage Sense (21)
Motor (42 VAC)
115 VAC
Motor (42 VAC)

Function

14 pin con-
nector for
wire feeder
connectivity.

G

F

E

M

N

D

B

A

J

I

L

K

C

H

14-PIN CONNECTOR FOR WIRE FEEDER

14-PIN CONNECTOR
FOR WIRE FEEDER

6-PIN REMOTE
CONTROL CONNECTOR