1 smart fan mode configuration – IEI Integration TANK-820-H61 v2.00 User Manual
Page 91
TANK-820 Em b e d d e d S ys te m
P a g e 78
o
+CPU_CORE
o
+V5S
o
+V12S
o
+1.5V_DDR3
o
VSB5V
o
VCC3V
o
VSB3V
o
VBAT
Sm art Fan Fu n ctio n [En a b led ]
Use the Smart Fan Function option to enable or disable the smart fan function.
Disabled
Disables the smart fan function.
Enabled
D
EFAULT
Enables the smart fan function.
5.3.9.1 S m a rt Fa n Mo d e Co n fig u ra tio n
Use the Smart Fan Mode Configuration submenu (BIOS Menu 15) to configure the
smart fan temperature and speed settings.
Aptio Setup Utility – Copyright (C) 2012 American Megatrends, Inc.
Advanced
Smart Fan Mode Configuration
Smart Fan control
[Auto PWM Mode]
Temperature of Off
75
Temperature of Start
80
Start PWM
30
Slope(Duty Cycle)
[4]
Fan 2 Smart Fan control
[Auto RPM Mode]
First Boundary Temperature
60
Second Boundary Temperature
50
Third Boundary Temperature
40
Fourth Boundary Temperature
30
Smart Fan Mode Select
---------------------
: Select Screen
↑ ↓: Select Item
Enter
Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
Version 2.15.1226. Copyright (C) 2012 American Megatrends, Inc.
BIOS Menu 15: FAN Configuration