beautypg.com

1 smart fan mode configuration – IEI Integration TANK-820-H61 v2.00 User Manual

Page 91

background image

TANK-820 Em b e d d e d S ys te m

P a g e 78

o

+CPU_CORE

o

+V5S

o

+V12S

o

+1.5V_DDR3

o

VSB5V

o

VCC3V

o

VSB3V

o

VBAT

 Sm art Fan Fu n ctio n [En a b led ]

Use the Smart Fan Function option to enable or disable the smart fan function.

Disabled

Disables the smart fan function.

Enabled

D

EFAULT

Enables the smart fan function.

5.3.9.1 S m a rt Fa n Mo d e Co n fig u ra tio n

Use the Smart Fan Mode Configuration submenu (BIOS Menu 15) to configure the

smart fan temperature and speed settings.

Aptio Setup Utility – Copyright (C) 2012 American Megatrends, Inc.

Advanced

Smart Fan Mode Configuration

Smart Fan control

[Auto PWM Mode]

Temperature of Off

75

Temperature of Start

80

Start PWM

30

Slope(Duty Cycle)

[4]


Fan 2 Smart Fan control

[Auto RPM Mode]

First Boundary Temperature

60

Second Boundary Temperature

50

Third Boundary Temperature

40

Fourth Boundary Temperature

30


Smart Fan Mode Select





---------------------
: Select Screen
↑ ↓: Select Item
Enter

Select

+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit

Version 2.15.1226. Copyright (C) 2012 American Megatrends, Inc.