beautypg.com

Extron Electronics XTRA Full Rack Series User Guide User Manual

Page 17

background image

i

High pass filter toggle switch — Use a small screwdriver to toggle this recessed

two-position toggle switch that alternates between Off (no filtering) and 80 Hz. The
XPA 2002-70V and XPA 2002-100V have 2 switches, one for each output channel.
The XPA 2003C-70V and XPA 2003C-100V have one switch for the line distribution
output channel (channel 3). Setting the switch to 80 Hz prevents the saturation of
the speaker input transformers by low frequency signals. Saturation may result in
undesired overheating of the speaker transformers.

80 Hz

OFF

CH 2

80 Hz

OFF

CH 1

HPF

80 Hz

OFF

CH 3

HPF

XPA 2002-70V
XPA 2002-100V

XPA 2003C-70V
XPA 2003C-100V

NOTE: It is recommended that the high pass filter be left in the On position

unless filtering is applied to the signal upstream of the amplifier.

j

Mono audio output connector — Marked “+” and “-”, wire the included 2-pole,

5 mm screw lock captive screw connector for mono audio. See steps 1 and 2 on
the following page. Output is designed to power 70 V (XPA 2002-70V and XPA
2003C-70V) or 100 V (XPA 2002-100V and XPA 2003C-100V) line distribution
systems and is rated at 200 watts.

NOTE: You must use Class 2 wiring for this output to comply with UL

requirements.

XPA 2003C-70V

XPA 2002-70V

2

70V

1

OUTPUTS

3

70V

OUTPUTS

XPA 2003C-100V

XPA 2002-100V

2

100V

1

OUTPUTS

3

100V

OUTPUTS

CAUTION: Do not short out the “+” and “-” connectors with each other or

to ground; doing so will short the outputs and may damage the
amplifier.

XTRA Full Rack Power Amplifier Series • Operation

12