beautypg.com

Seite19, External synchronization of the visualizer, For specialists only) – WolfVision VZ-35 User Manual

Page 19

background image

19

EXTERNAL SYNCHRONIZATION OF THE VISUALIZER

(for specialists only)

professional video mixer

professional video camera

composite video / Y/C signal

BB / sync signal

IN

OUT

IN

O

U

T

O

U

T

O

U

T

IN

IN

BB / sync signal

composite video / Y/C signal

If Visualizer images are mixed and processed (fade-in, fade-out, mix/wipe) with images from one or more
video cameras using a special effect unit without TBC (time base corrector), all units connected must be
genlocked.

Genlocking is achieved by supplying the same composite video signal (VBS) or black burst (BB) signal to
the Extern Sync input (=Genlock input) of each unit connected.

In order to genlock the Wolfvision Visualizer with another video signal, simply connect this signal to the
Sync input (#33) of the Visualizer where a composite video or a black burst signal can be connected

For fine adjustment of color-phase (SC) and H-phase, use the key combination: Save + Zoom-close +
Zoom-wide in order to unlock the camera controls and then press the Menu key.

After that press the Function up or Function down key until the word "H-PHASE" appears on the monitor.
The Visualizer can be perfectly synchronized on the horizontal phase of the other camera(s) using the Data
up and Data down keys.

For fine adjustment of the SC-phase (color phase) press the Function up or Function down key until
"SC" and "0/180" appears on the monitor. Start with 0/180 for coarse adjustment followed by SC for
fine adjustment.

At the end of the adjustments press the Menu key for leaving the menu and locking the camera controls.

Genlock operation with a playback signal of a video recorder is only possible if the signal is time base
corrected via a TBC device.