Symptom D: Magnet or field on channel 1 does not disengage when input is switched
Probable Cause
Solution
Channel 2 override input activated
Check status of channel 2 override, and release if
activated.
Faulty control
Replace main control logic board.
Symptom E: Magnets or fields do not appear to have enough torque
Probable Cause
Solution
Dip switches improperly set
Check dip switch settings per chart found on page 9 and
reset if necessary.
Magnets or fields incorrectly wired
Check wiring between control and magnets or fields.
Require if necessary.
Torque adjust potentiometers set too low
Check setting of torque adjust potentiometers and
increase if required.
Clutches or brakes incorrectly sized
Verify proper size by repeating sizing process in Warner
Electric Master Catalog, form P-137.
Symptom F: Outputs don’t switch; inputs don’t switch
Probable Cause
Solution
Input incorrectly wired
Check for proper wiring schemes and Require if necessary.
Faulty switching device
Check for proper operation and replace if defective.
Control switches on main board not set
Check positions of switches on main board and reset for
properly
proper configuration.
Faulty control
Replace main control logic board.
Replacement Parts
CBC-750-6
Complete Control Less Cover
6041-448-001
Main Control Logic Board Assembly
6041-101-001
Cover
6041-101-001
Fuse F1
458-8001-074
Fuse F2
458-8001-010
CBC-750-24
Complete Control Less Cover
6041-448-002
Main Control Logic Board Assembly
6041-101-002
Cover
6041-101-004
Fuse F1
458-8001-074
Fuse F2
458-8001-028
CBC-750-90
Complete Control Less Cover
6041-448-003
Main control Logic Board Assembly
6041-101-003
Cover
6041-101-004
Fuse F1
458-8001-074
Fuse F2
458-8001-026