Clutch/
OEX Switch
Overlap Pot
Brake
(CBC-700-90) (CBC-700-90)
Model
Switches On
%
SF/PB-120
1&2
0
SF/PB-170
1&2
0
SF/PB-250
1
5
SF/PB-400
3
20
SF-500
2&3
10
PC/PB-500
2&3
15
SF-650
2
15
PB-650
2
15
SF-825
4
30
SF-825 brg
4
25
PC/PB-825
3
20
SF-1000
4
35
PC/PB-1000
4
30
SF-1225
All open
60
PC/PB-1225
4
40
SF-1525
All open
70
PC/PB-1525
All open
60
EC-375
1
8
EB-375
1
6
EC-475
2&3
12
EB-475
2&3
10
EC-650
2
15
EB-650
2
15
EC-825
4
26
EB-825
3
20
EC-1000
4
30
EB-1000
4
30
EC-1225
All open
60
EB-1225
All open
55
UM/EM-50
1
5
UM/EM-100
2&3
8
UM/EM-180
2&3
8
UM/EM-210
2
20
UM/EM-215
2
20
EP-170
1&2
0
EP-250
1
5
EP-400
3
20
EP-500
2&3
15
EP-825
4
25
EP-1000
4
35
EP-1525
All open
70
AT-25
3
10
AT-55
3
20
AT-115
3
40
Clutch/
OEX Switch
Overlap Pot
Brake
(CBC-700-90) (CBC-700-90)
Model
Switches On
%
SF/PB-120
1&2
0
SF/PB-170
1&2
0
SF/PB-250
1
5
SF/PB-400
3&4
20
SF-500
2&3
10
PC/PB-500
2&3
15
SF-650
2
15
PB-650
2
15
SF-825
3
30
SF-825 brg
3
25
PC/PB-825
3&4
20
SF-1000
3
35
PC/PB-1000
3
30
SF-1225
4
60
PC/PB-1225
3
40
SF-1525
4
70
PC/PB-1525
4
60
EC-375
1
8
EB-375
1
6
EC-475
2&3
12
EB-475
2&3
10
EC-650
2
15
EB-650
2
15
EC-825
3
26
EB-825
3&4
20
EC-1000
3
30
EB-1000
3
30
EC-1225
4
60
EB-1225
4
55
UM/EM-50
1
5
UM/EM-100
2&3
8
UM/EM-180
2&3
8
UM/EM-210
2
20
UM/EM-215
2
20
EP-170
1&2
0
EP-250
1
5
EP-400
3&4
20
EP-500
2&3
15
EP-825
3
25
EP-1000
3
35
EP-1525
4
70
AT-25
3&4
10
AT-55
3&4
20
AT-115
3&4
40
Clutch/
OEX Switch
Overlap Pot
Brake
(CBC-700-24) (CBC-700-24)
Model
Switches On
%
SF/PB-120
1
0
SF/PB-170
1
0
SF/PB-250
1
3
SF/PB-400
2
10
SF-500
2
16
PC/PB-500
2&3
10
SF-650
3&4
18
PB-650
2
16
SF-825
3&4
20
SF-825 BRG
3&4
20
PC/PB-825
3&4
15
SF-1000
3&4
25
PC/PB-1000
3&4
30
PC/PB-1225
3&4
22
SF-1225
3
40
PC/PB-1225
3
38
SF-1525
4
70
PC/PB-1525
3
45
SF-1525 HT
4
80
EC-375
1
5
EB-375
1
5
EC-475
2&3
12
EB-475
2&3
10
EC-650
3&4
15
EB-650
2
15
EC-825
3&4
20
EB-825
3&4
20
EC-1000
3&4
30
EB-1000
3&4
30
EC-1225
3
40
EB-1225
3
40
UM/EM-50
1&2
5
UM/EM-100
2&3
5
UM/EM-180
2&3
5
UM/EM-210
2
8
UM/EM-215
3&4
8
EP-250
1
3
EP-400
2
10
EP-500
2
16
EP-825
3&4
20
EP-825 HT
4
*0
EP-1000
3&4
25
EP-1525
3
70
AT-25
2
4
AT-55
2
6
AT-115
3&4
14
5
Warner Electric • 800-825-9050
P-272 819-0527 5/12
CBC-700-90 (current model)
(with OEX on/off switch)
CBC-700-90 (early model)
(without OEX on/off switch)
CBC-700-24
This is a floating-type control and is not refer-
enced to aC ground. Under no circumstances should any of
the output wire leads be connected to earth or chassis ground
as the unit will be destroyed.
(Example shows 2 & 3 on for 15 ms duration)
OPEN
1
2
3
4
anti-Overlap Time Delay
Potentiometer PI
OEX Duration Settings
*For the units with a shuttle armature, the
overlap setting should be zero (0).
Control adjustments
The duration of the OEX Pulse and Anti-Overlap Time Delay can be optimized to a specific clutch/
brake. The chart above designates switch settings for 90 and 24 VDC Warner Electric clutch/brake
models.