Warner Electric CBC-700 User Manual
Page 3
3
Warner Electric • 800-825-9050
P-272 819-0527 5/12
Specifications
Input:
CBC-700-90:
120 VAC ± 10%, 50/60 Hz
CBC-700-24:
24 VAC ± 10%, 50/60 Hz
Output Voltage:
Steady State:
CBC-700-90:
90 VDC
CBC-700-24:
24 VDC
Overexcitation:
CBC-700-90:
340 VDC
CBC-700-24:
105 VDC
Output Current: (per channel, alternately)
CBC-700-90:
0.5 Amps max.*
CBC-700-24:
3.5 Amps max.
Circuit Protection: (fusing)
CBC-700-90:
1.6 Amp, 250 Volt, 5 x 20 mm, F/A
CBC-700-24:
5 Amp, 250 Volt, 5 x 20 mm, F/A
* Caution: It will not work with the SF1525HT-90
OEX Pulse Duration: (current model–with OEX on/off switch)
700-24 Switch Position
1 & 2
1
2 & 3
2
3 & 4
3
4
700-90 Switch Position
1 & 2
1
2 & 3
2
3
4
All Open
Time (milliseconds)
8
11
15
22
34
50
100
OEX Pulse Duration: (early model–without OEX on/off switch)
Switch Position
1 & 2
1
2 & 3
2
3 & 4
3
4
Time (Milliseconds)
7
10
15
22
34
51
100
anti-Overlap adjustment:
CBC-700-90:
0 - 100 ms
CBC-700-24:
0 - 50 ms
Switching Inputs:
Two optically isolated, 10-30 VDC
Min. and Max. current input 3.1 - 9.5mA
Maximum off-state leakage < 2 mA
ambient Temperature:
0° to 140° F (-18° to + 60° C)
auxiliary Supply:
12 VDC, 250 mA maximum
Enclosure:
Rated NEMA 13 with optional enclosure (P/N 6042-101-004 )
Reorder Information
Model
Part No.
CBC-700-24
6042-448-002
CBC-700-90
6042-448-003
CBC-700-90C
6042-448-013
Enclosure
6042-101-004
Note: CBC-700-90C has a right angle terminal strip and is conformally coated.