Warner Electric CBC-200C Single User Manual
Page 9
9
Warner Electric • 800-825-9050
P-269 • 819-0407
CBC-200-2
External Level Adjust with Internal
Current Limit Adjust
❑
1. Wire the external level adjust potentiome-
ter on Terminal Block TB-2 as shown in the
diagram. (See Figure 5)
❑
2. If the accessory pot kit is used, wire
according to the colors as shown in the
diagram.
❑
3. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull out of the terminals.
Note: The level adjustment controls both the
current adjustable output, channel 1 as well as
the steady state output, channel 2.
❑
4. After the pot(s) has been wired to the
appropriate terminal block, mount the PCB
and bracket assembly and reattach to the
chassis with the four screws removed in step
2 above.
❑
5. For the CBC-200-2 reattach the internal
potentiometer knob.
❑
6. Double check all wiring for both the
potentiometer and the main terminal block
to insure proper connections.
CBC-200-3
External Current Limit and Level Adjust
❑
1. Wire the external current limit adjust
potentiometer to Terminal Block TB-3 for
Channel 1 as shown in the diagram.
(See Figure 7)
❑
2. If the accessory pot kit is used, wire per
the color codes as shown.
❑
3. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull out of the terminals.
❑
4. Wire the external level adjust potentiome-
ter to Terminal Block TB-2 as shown in the
diagram. (See Figure 7)
❑
5. If the accessory pot kit is used, wire per
the color codes as shown.
❑
6. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull out of the terminals.
Note: The level adjustment controls both the
current adjustable output, channel 1 as well as
the steady state output, channel 2.