Warner Electric CBC-200C Single User Manual
Page 3
Specifications
Input Power:
120 VAC, +10%, -15%, 50/60 Hz,
single phase, 215 VA maximum.
Output: Pulse-width modulated full wave rectified
DC. Constant current, switch selectable
ranges, for one channel and fixed 90VDC
second channel, designed for 90 volt DC
clutches and brakes.
Ambient Temperature: -32˚ F to + 113˚F (0˚C to + 45˚)
with plastic cover installed. -32˚F to +150˚F
(0˚C to +66˚C) with plastic cover removed, or
board assembly only.
Circuit Protection: Internal short circuit protection
on outputs, but no circuit protection for AC
ground faults. Optional customer supplied
fusing on AC line, 1.5 amps, 250 VAC
Fast-Acting type fuse recommended.
Control Adjust: CBC-200 and CBC-200-C via front
panel potentiometer for current adjustment.
CBC-200-1 and CBC-200-C1 via external
mounted potentiometer for current adjustment.
CBC-200-2 and CBC-200-C2 current
adjustment via front panel potentiometer and
output level adjust via external potentiometer.
CBC-200-3 and CBC-200-C3 both current
adjust and limit adjustment are via external
potentiometers.
Status Indicators: “POWER” – green LED indicating
AC power is applied to the control.
“SHORT” – red LED indicating that a short
circuit condition exists on one or both of
the outputs.
Internal Adjustments: Current Range Selection via
DIP switch, SW1
Current Ranges:
Switch Setting
1
2
3
4
5
Max Output, ma
60
175
245
305
533
3
Warner Electric • 800-825-9050
P-269 • 819-0407
External Switching: Mechanical or electromechanical
Electromechanical
Customer supplied; 1 amp, 125 V minimum
rating.
Solid-state NPN isolated transistor
Customer supplied; 2 amp, 250V minimum rat-
ing. Maximum off state leakage current < 1 ma.
External Pots:
Remote current adjust pot
customer supplied; 10,000 ohm, 2 watt, linear,
maximum distance from control to potentiome-
ter not to exceed 10 feet.
Optional Accessory Pot Kit;
part number, 6011-101-002
Remote Level adjust pot
Customer supplied; 5,000 ohm, 2 watt, linear,
maximum distance from control to potentiome-
ter not to exceed 10 feet.
Optional Accessory Pot Kit;
part number, 6011-101-001.
Wiring Entrance: Two 7/8” diameter entrance holes
located on the bottom of the control chassis on
enclosed units. No conduit entrances are on
chassis mount versions.
Enclosure: Rated NEMA 1 only – Control must be
kept clear of foreign materials, dust, grease and
oil which might affect its operation.
Part Numbers:
Enclosed Versions
CBC-200
6011-448-001
CBC-200-1
6011-448-002
CBC-200-2
6011-448-003
CBC-200-3
6011-448-004
Chassis Versions
CBC-200-C
6011-448-005
CBC-200-C1
6011-448-006
CBC-200-C2
6011-448-007
CBC-200-C3
6011-448-008