Technical details – Vestil CART-S-FR User Manual
Page 11
The standard EN 1570 does not establish the
additional requirements for:
~ Operation in severe conditions (e.g. extreme climates, freezer
applications, strong magnetic fields.).
~ Operation subject to special rules (e.g. potentially explosive
atmospheres, mines).
~ Handling of loads, the nature of which could lead to dangerous
situations (e.g. molten metal, acids, radiating materials, especially
brittle loads).
~ Hazards occurring during construction, transportation and
disposal.
~ Equipment installed on the load platform or replacing it.
~ Integration into systems or other machines, control from more
than two control stations etc.
~ Cable-less controls.
~ Lifting tables where the hydraulic pressure is derived directly
from gas pressure.
TECHNICAL DETAILS:
Hydraulic Fluid:
ISO VG22
Hydraulic Hoses:
TRACTOR 1T EN 853 1SN
Insert:
MF2000
–
Multifit
Type
Tube:
Oil
resistant
synthetic
rubber
Reinforcement:
One high tensile steel braid
Cover: Environmental resistant synthetic rubber
Max. working pressure: 225 bar (3260 psi)