TROUBLESHOOTING

GUIDE

WARNING: Carelessness during maintenance could result in serious injury.

Identify all potential hazards and apply the safety procedures used at your work site before

beginning troubleshooting or repairs. Disconnect / disable all energy sources with proper
lock-out/tag-out procedures

 Before performing any troubleshooting or repairs, the load must be removed from the platform;

then either raise the platform and install the maintenance props, or fully lower the platform.

 Only qualified individuals trained to understand mechanical devices and their associated electrical

and hydraulic circuits, along with the hazards that could result from them, should attempt
troubleshooting and repair of this equipment.

Contact the factory for answers to questions not addressed in this manual

Problem: Possible

cause(s): Action:

1. Platform does not raise

a. Load weight exceeds capacity

b. Oil is low

c. Pinched

hose

d. Relief valve set too low

a. Remove part of the load

b. Fill oil to within on inch of the top

of the reservoir

c. Connect as necessary

d. Increase only as necessary

2. Foot pedal goes down hard

but platform does not rise

a. Particle of dirt under the pressure

relief

b. Particle of dirt under the inlet check

a. Lower platform – disassemble,

clean & reassemble pressure

relief.

b. Lower platform – disassemble

clean & reassemble inlet check

valve

3. Platform rises only under no

load or when rapidly pumped

or

Pedal strokes without

being pumped.

a. Pump is “air locked”.

b. Inlet check valve has foreign

material on seat

c. Relief setting is out of adjustment

d. Foreign material on relief valve set

a. Bleed air from system

b. Remove and clean inlet ball and

seat.

c. Adjust relief setting higher

d. Lower platform – disassemble

clean & reassemble inlet check

valve

4. Platform rises when the

pump is stroked but lowers

during the return stroke.

a. Outlet check is leaking.

a. Clean foreign material from ball

and seat.

5. Platform rises but takes too

much effort

a. Switch pump displacement speed.

a. Slide locking collar back