4.7.1. Editing a Test Record
To edit a test record:
1. Double click anywhere on the displayed test record. The following window will be
displayed:
2. You can edit the test record header information (such as Company, Station, Circuit,
Manufacturer, etc.) by entering data in the corresponding fields at the top of the screen.
3. You can also change the knee point marker and the frequency. The nameplate ratios for
each tap connection can be edited as well. Test notes can be added or modified for each
tap connection.
NOTES
• If the knee point marker is changed, the CT Excitation Plot will be updated
accordingly to display the selected knee point marker.
• If the nameplate ratio is changed for a tap connection, the percentage
error will be automatically re-calculated.
• The frequency is for reference only. The CT test is conducted at the
supplied line voltage and frequency.
4. You can access the Notepad by clicking on the “Notepad” button. Enter any relevant
notes about the test in the Notepad and then click on the “OK” button.