beautypg.com

Vanguard CT-7500 S2 User Manual

Page 93

background image

REV 2 CT-7500 S2 USER’S MANUAL

88

4.2

Performing a Transducer Self-Test

You can check the transducer electronics by connecting the transducer to the CT-7500 S2 and
running a transducer self-test using the instructions below:

a. Start from the “START-UP” menu:

Press the

[4]

key (DIAGNOSTICS).

b. The following screen will be displayed:

Press the

[3]

key (TEST TRANSDUCER).

c. The following screen will be displayed:

Move the transducer slider to a known distance and observe the display.

d. The screen will be updated with the new transducer position information:

If the transducer was moved 5 inches, the screen should display 5.00 IN. You can
continue to move the transducer slider and observe the screen values to make sure they
are correct. Press the

[STOP]

key to end the test and return to the “START-UP” menu.

TRANSDUCER TEST:
1= 5.00 IN / 360.0

x

2= 0.00 IN / 000.0

x

2= 0.00 IN / 000.0

x

TRANSDUCER TEST:
1= 0.00 IN / 000.0

x

2= 0.00 IN / 000.0

x

2= 0.00 IN / 000.0

x

1. SLOW CLOSE TEST

2. CHECK HOOKUP

3. TEST TRANSDUCER

4. NEXT PAGE

1. TIME BRKR 02/14/11

2. GET RSLT 09:35:45

3. SETUP

4. DIAGNOSTICS