Front Panel Description
The Analyzer has the following features on the front:
[1] Power Switch (black): 1 = On and 0 = Off.
[2] LCD Menus: Allows you to configure Summit T3-16 and view 
status.
[3] Navigation Buttons: Navigate through the LCD menu.
[4] Speed LEDs: Indicate speed setting the analyzer is using for 
each traffic direction.
[5] UPSTREAM [15:8] and UPSTREAM [7:0] connectors:
Connection to the probe for the capture of upstream direction 
of the link.
[6] DOWNSTREAM [15:8] and DOWNSTREAM [7:0]
connectors: Connection to the probe for the capture of 
downstream direction of the link.
[7] Trigger IN and Out: Provide external trigger capabilities. You
can configure Summit T3 to trigger external equipment using 
Trigger Out. You can use Trigger In to trigger the Analyzer 
from another device. 
[8] USB Type B Host Machine Connector: To connect the
Analyzer to the host machine using a USB connection.
[9] Ethernet Port: 1 GIGE Connectivity allows connection to the
analyzer through an Ethernet network.
[10] Expansion Slot: CATC Sync Expansion Card to use the
Teledyne LeCroy CrossSync application.
LCD Menus
The Summit T3-16 has a front LCD panel that displays the 
computer name that is currently connected to the system, the unit 
serial number, and the current network configuration. If no 
computer is connected to the unit, the LCD panel displays 
Available.
The LCD panel also allows you to configure network settings for 
the analyzer. Use the Up and Down keypad buttons to cycle 
through the menu. Press the Center button to select.
Setup Static or Dynamic IP Mode
1.
Use the Up and Down buttons to navigate to the 
Set IP Configuration menu.
2.
Press the Center button to start the setup.
3.
Use the Up and Down buttons to select Static or Dynamic 
IP configuration. 
4.
If you select the Static IP network configuration, you must 
specify the IP address, Subnet mask, and Gateway. Use the 
Up and Down buttons to navigate to the IP address, Subnet 
mask, or Gateway. 
5.
Press the Center button to enter edit mode.
6.
In edit mode, use the Left and Right buttons to move the 
blinking cursor to any digit.
7.
Use the Up and Down buttons to modify the digit.
8.
After finishing modifications to the IP address, Subnet mask, 
or Gateway, press the Center button to return to the menu.
9.
After you specify the IP address, Subnet mask, and Gateway, 
use the Up and Down buttons to navigate to the Accept and 
Reboot menu item. Press the Center button to apply the new 
settings and restart the analyzer. 
Note: To cancel your modifications, select the 
Cancel Changes menu item.
Warning
Do not open the enclosure. No operator serviceable 
parts are inside.
4
Rear Panel Description
The rear panel of the Analyzer has: 
Wide-range AC Connector Module
•
Power socket
•
Enclosed 5.0 A 250 V fuse
Expansion Slot: Future use
Warning!
For continued protection against fire, replace fuse 
only with the type and rating specified above.
5
Interposers and Probes
Gen3 Slot Interposer
The Gen3 Slot Interposer is designed for use with the 
Summit T3-16 Analyzer and supports lane widths from 
x1 to x16 at data rates of 2.5 GT/s (Gen1), 
5.0 GT/s (Gen2), or 8.0 GT/s (Gen3). A separate interposer 
is used for each lane width that you would like to probe. 
Lane reducers should NOT be used with the Gen3 Slot 
Interposer. For lane widths up to x8, one Analyzer Y-cable 
is required. For x16 applications, two Analyzer Y-cables are 
required.
Warning
Interposer has static-sensitive components. 
Handle only at static-safe work stations.
Gen3 MidBus Probe
The Gen3 MidBus Probe is designed for use with the 
Summit T3-16 Analyzer and supports lane widths from 
x1 to x16 at data rates of 2.5 GT/s (Gen1), 
5.0 GT/s (Gen2), or 8.0 GT/s (Gen3).
6