beautypg.com

Teledyne LeCroy WaveLink Differential Probe Series (4, 6 GHz) User Manual

Page 68

background image

62

923175-00 Rev A

Description

Minimum Requirements

Example Test Equipment

Oscilloscope, High BW

1

BW

³

6 GHz

Teledyne LeCroy: WaveMaster 8600A,
WavePro 760 Zi, WaveMaster 806 Zi/Zi-A

Oscilloscope, High BW

2

BW

³

4 GHz

Teledyne LeCroy: WaveMaster 804Zi-A,
WavePro 740 Zi, WaveRunner 640 Zi

Oscilloscope, High Impedance

200 mV/div - 2 V/div scale
factor 1 MΩ input impedance
ProBus interface

Teledyne LeCroy: WavePro 7300 or
WaveRunner 6200, WavePro 735 Zi-A,
WaveRunner 6 Zi

Digital Multimeter

AC: 0.2% accuracy

to

measure 200 mV and 2 V

rms

@

1 kHz 6½ digit resolution

Agilent Technologies: 34401A, or Fluke:
8842A-09, or Keithley: 2001

Oscillator/Function Generator

Sine Wave output, adjustable
from 500 mV to 4 Vp-p (357

mV to 2.83 V

rms

) at 70 Hz

Stanford Research: Model DS340,or
Agilent Technologies: 33120A, or Leader:
LAG-120B

Pulse Generator

12 ps, -5 V

out

, 2.4 mm output

Picosecond Pulse Labs: 4015D-215

Calibration Fixture

3

See Preliminary Procedure

Teledyne LeCroy: ProLink-CF01

Calibration Fixture

4

See Preliminary Procedure

Teledyne LeCroy: ProBus-CF01

Terminator, Precision, BNC

50 Ω ± 0.05%

Teledyne LeCroy: TERM-CF01

Characterization Fixture

5

Teledyne LeCroy: PCF-200

SMA to BNC Adapter

Female SMA to male BNC

Pomona Electronics: 4289