beautypg.com

LEESON SM-Basic Series Sub-Micro Inverters (Obsolete) User Manual

Page 44

background image

40

NOTE: The speed source displays will flash when the speed reference source is changed while the
drive is running to indicate that the new speed reference source is active.

17.3

STATUS AND WARNING MESSAGES

SPEED SOURCE DISPLAYS

SPEED SOURCE DISPLAYS

SPEED SOURCE DISPLAYS

SPEED SOURCE DISPLAYS

DISPLAY

DISPLAY

DISPLAY

DISPLAY

DESCRIPTION

DESCRIPTION

DESCRIPTION

DESCRIPTION

CP

CONTROL PAD: Speed is set using the V and W buttons on the front of the drive.

EU

EXTERNAL VOLTAGE: Speed is controlled by a speed pot.

JG

JOG: The drive is in Jog mode, and the speed is set by Preset Speed #2 (Parameter 32).

OP

MOP (Motor Operated Pot): Contacts wired to two of the TB-13 terminals are used to increase
and decrease the drive speed. See Parameters 10, 11, and 12.

P1 - P7

PRESET SPEEDS #1-7: Speed is set by the indicated Preset Speed (Parameters 31-37).

DISPLAY

DISPLAY

DISPLAY

DISPLAY

DESCRIPTION

DESCRIPTION

DESCRIPTION

DESCRIPTION

br

DC BRAKING: The DC braking circuit is activated.

cE

COMPATIBLE EPM: An EPM with a previous parameter version has been installed, and an
attempt was made to change the programming. The drive will operate with the EPM installed,
but the parameters cannot be changed. Refer to setting 06 (TRANSLATE) in Parameter 48.

CL

CURRENT LIMIT: The output current has exceeded the CURRENT LIMIT setting (Parameter 25)
and the drive is reducing the output frequency to reduce the output current. If the drive remains
in CURRENT LIMIT for too long, it can trip into a CURRENT OVERLOAD fault (PF).

Er

ERROR: Invalid data has been entered or an invalid command was attempted.

GE

"GE" will be displayed if an attempt is made to change the OEM default settings when the drive is
operating in the OEM mode (see Parameter 48).

GF

If "GF" is displayed when a RESET OEM is attempted, it indicates that the OEM defaults in the
EPM are corrupted. If "GF" is displayed upon power-up, it indicates that the OEM defaults and
the user settings in the EPM are corrupted. Refer to Section 13.2.

LC

FAULT LOCKOUT: The drive has failed three restart attempts and now requires a manual reset.

SP

START PENDING: "SP" blinks during the interval between restart attempts.
DECEL OVERRIDE (both upper decimal points blinking): The drive has stopped decelerating to
avoid tripping into an HF fault due to regenerative energy from the motor.

STATUS AND WARNING MESSAGES

STATUS AND WARNING MESSAGES

STATUS AND WARNING MESSAGES

STATUS AND WARNING MESSAGES